Product Identification

Product ID:KODAK AQUA-IMAGE ADDITION PEN
MSDS Date:11/03/1993
FSC:6750
NIIN:00D004978
MSDS Number: BYTRY

Responsible Party
EASTMAN KODAK COMPANY
343 STATE STREET
ROCHESTER, NY 14650
US

Emergency Phone: 716-722-5151

Info Phone: 800- 242-2424

Cage: 19139

Contractor
EASTMAN KODAK CO GOVERNMENT MARKETS CONTRACTS
ROCHESTER, NY 14650-1115 US

Telephone: 716-722-5151/(800) 242-2424

Cage: 19139

Ingredients

METHYL ETHYL KETONE

CAS: 78-93-3

RTECS: EL6475000

Fraction By Weight: <50%

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ETHYLCELLULOSE

CAS: 9004-57-3

RTECS: FJ5950500

Fraction By Weight: 25-30%


EPOXY RESIN

Fraction By Weight: 10-15%


TOLUENE

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: <5%

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


PIGMENTS

Fraction By Weight: <1%

Hazards

Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: EXPECTED TO BE A LOW
HAZARD FOR RECOMMENDED HANDLING. EYES: CAUSES IRRITATION. SKIN:
CAUSES IRRITATION. INGESTION: EXPECTED TO BE A LOW INGESTION
HAZARD.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHALATION-IF SYMPTOMATIC, MOVE TO FRESH AIR. GET MEDICAL
ATTENTION IF SYMPTOMS PERSISTS. EYES-IMMEDIATELY FLUSH WITH PLENTY
OF WATER FOR AT LEAST 15 MIN. GET MEDICAL ATTENTION.
SKIN-IMMEDIATELY FLUSH WITH PLENTY OF WATER & WASH WITH A
NON-ALKALINE SKIN CLEANER. GET MEDCIAL ATTENTION. INGESTED-DRINK 1
OR 2 GLASSES OF WATER. SEEK MEDICAL ATTENTION.

Fire Fighting

Flash Point:<100F,<38C
Extinguishing Media:WATER SPRAY, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING. FIRE OR EXCESSIVE HEAT MAY PRODUCE HAZARDOUS
DECOMPOSITION PRODUCTS.
Unusual Fire/Explosion Hazard:NONE, BASED ON LIMITED QUANTITY OF FLUID
CONTAINED IN PEN. HOWEVER, COMPONENT IS EXTREMELY FLAMMABLE.

Accidental Release

Spill Release Procedures:NONE.
Neutralizing Agent:NONE.

Handling

Handling and Storage Precautions:KEEP CONTAINER CLOSED. KEEP FROM
CONTACT WITH OXIDIZING MATERIALS.
Other Precautions:AVOID CONTACT WITH EYES, SKIN AND CLOTHING. USE WITH
ADEQUATE VENTILATION. WASH THOROUGHLY AFTER HANDLING.

Exposure Controls

Respiratory Protection:NONE SHOULD BE NEEDED.
Ventilation:GOOD GENERAL VENTILATION (10 AIR CHANGES PER HOUR) SHOULD
BE USED. VENTILATION RATES SHOULD BE MATCHED TO CONDITIONS.
Protective Gloves:WEAR IMPERVIOUS GLOVES.
Eye Protection:SAFETY GLASSES WITH SIDE SHIELD.
Other Protective Equipment:EYE BATH, WASHING FACILITIES, SAFETY SHOWER.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
NOTE: THIS ITEM IS A PEN AND KODAK DOES NOT REGULATE THIS ITEM FOR
TRANSPORTATION, THEY CONSIDER THIS ITEM AS NONHAZARDOUS. PER
MANUFACTURER (770-455-0123, KODAK).

Chemical Properties

HCC:F3
Boiling Pt:B.P. Text:176F,80C
Vapor Pres:47.8 MBAR
Vapor Density:2.8
Spec Gravity:0.9
Solubility in Water:SLIGHT-MODERATE
Appearance and Odor:LIQUID, PINK COLOR, SLIGHT ODOR.
Percent Volatiles by Volume:>50

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NON-HAZARDOUS. BASED ON LIMITED QUANTITY
OF FLUID CONTAINED IN PEN.
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:MAY BE DISPOSED OF WITH GENERAL OFFICE WASTES.
DISCHARGE, TREATMENT, OR DISPOSAL MAY BE SUBJECT TO NATIONAL,
STATE, OR LOCAL LAWS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.